Usb Compliance Hard Disk Controller Driver Download For Windows



From the resulting download page, download the package. This Smart Array firmware will recommend updates for some SCSI disk drive models after the Smart Array firmware has been installed. To avoid notification during the POST routine, update any applicable hard disk drives before updating the Smart Array firmware. Download the USR5637Voice64bit.EXE file to a temporary location on your computer's hard disk drive. Double-click the file in Windows Explorer and follow the on-screen instructions. Insert your modem to complete the installation. USR5637Voice64bit.EXE: 433 KB: 28-01-11: 32 Bit Drivers for Windows XP, 2003, Vista, 2008, Win 7, Win 8, and Win 10‡.

  1. Usb Compliance Hard Disk Controller Driver Download For Windows Xp
Printable version
ComplianceUsb Compliance Hard Disk Controller Driver Download For Windows
  1. USB3.0 Driver for Windows 10 (64-bit), 7 (64-bit) - Lenovo M50-70. Turkey Ukraine United Arab Emirates United Kingdom United States of America Uruguay US Downloads.
  2. Windows-compatible PC equipped with USB port. Intel chipset is recommended. The device may not perform to its full specs when used with an added USB 2.0 interface card. This product cannot be used with a USB 3.0 port that is not compatible with USB 2.0 specification.
  3. Note: The Intel® USB 3.0 eXtensible Host Controller Driver is not supported on Windows XP. and Windows Vista. This is a new version release: 5.0.4.43v2. Not sure if this is the right driver or software for your Intel® chipset? Run Intel® Driver & Support Assistant (Intel® DSA) to automatically detect driver or software updates.
Controller

* RECOMMENDED * Online ROM Flash Component for Windows - Smart Array 6i

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Firmware - Storage Controller
Version:2.84(A)(15 Jul 2008)
Operating System(s):
Microsoft Windows Server 2003
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Storage Server 2003
Microsoft Windows Unified Data Storage Server 2003 x64 Edition
Microsoft Windows 2000
Multi-part download
File name:cp009357.exe (909 KB)
File name:cp009357.md5 (48 Bytes)
This Smart Component contains firmware for the Compaq Smart Array 6i Controller.

Prerequisites:
This Smart Array firmware will recommend updates for some SCSI disk drive models after the Smart Array firmware has been installed. To avoid notification during the POST routine, update any applicable hard disk drives before updating the Smart Array firmware. Click here to obtain the list of affected disk drive models.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

0277860584fc9589d91baaf8581e802acc4252a2d8a858e07037bfd5fcfffc6fcp009357.exe
7f11ed590b9c3e188ad0190f5e5119e84dfd7dd566d356ba9d677a6a160a2935cp009357.md5

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:
Place the Smart Component in a temporary directory.

Double-click on the Smart Component.

Follow the directions given by the Smart Component.

Reboot your system if you would like the update to take effect immediately.

End User License Agreements:
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

The firmware update Version 2.48 contains critical bug fixes and is the minimum version required. Please perform the update at your earliest convenience.

HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps:

  • Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.
  • Place the firmware to be updated in the directory, /compaq/swpackages on the USB key.
  • Run Autorun from _autorunautorun_win.exe on the Firmware Maintenance CD from the USB key on a system
  • Select the Firmware Update tab
  • Click on the Install Firmware link to launch the HP Smart Update Manager
  • Follow the GUI to install the firmware on remote servers

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis initialization and I/O writes occurring on Raid 1 or Raid 1+0 volumes. This has only been observed in a rigorous test environment and has not been reported in a production environment.
  • Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked 'OK', prior to completing the rebuilding process.
  • Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes.

The firmware update Version 2.48 contains critical bug fixes and is the minimum version required. Please perform the update at your earliest convenience.

HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps:

  • Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.
  • Place the firmware to be updated in the directory, /compaq/swpackages on the USB key.
  • Run Autorun from _autorunautorun_win.exe on the Firmware Maintenance CD from the USB key on a system
  • Select the Firmware Update tab
  • Click on the Install Firmware link to launch the HP Smart Update Manager
  • Follow the GUI to install the firmware on remote servers
Version:2.84(A) (15 Jul 2008)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis initialization and I/O writes occurring on Raid 1 or Raid 1+0 volumes. This has only been observed in a rigorous test environment and has not been reported in a production environment.
  • Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked 'OK', prior to completing the rebuilding process.
  • Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes.

Version:2.80(B) (23 Jan 2008)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated the component installer. If you have previously updated to version 2.80, another update is not needed.

  • Fixed an issue that would downshift the entire bus for a single parity error.
  • Fixed a bus fault issue on dual bus I/O modules.
  • Changed the SCSI ID detection algorithm for SCSI disk drive that unexpectedly changes its SCSI ID, in configurations involving duplex backplanes.
  • Improved cache flushing and performance.
  • Updated the volume inquiry command for “Windows Server 2008” compliance.

Version:2.80(A) (25 Sep 2007)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Fixed an issue that would downshift the entire bus for a single parity error.
  • Fixed a bus fault issue on dual bus I/O modules.
  • Changed the SCSI ID detection algorithm for SCSI disk drive that unexpectedly changes its SCSI ID, in configurations involving duplex backplanes.
  • Improved cache flushing and performance.
  • Updated the volume inquiry command for “Windows Server 2008” compliance.

Version:2.76(A) (20 Mar 2007)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

  • Updated recommended hard drive firmware list with models that have been experiencing excessive SCSI command timeouts. When one of these drives is present, user will see a POST message recommending he upgrade the drive’s firmware. Failure to upgrade may result in the bus down-shifting from Ultra 320 to Ultra 3.

Version:2.74(A) (10 Jan 2007)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue where Windows Server x64 would hang or blue screen when the Smart Array driver is installed or upgraded on a system that has greater than 7GB RAM.

2. Fixed Array behavior to prevent unwanted device migrations by detecting conditions, where a SCSI disk drive unexpectedly changes its SCSI ID.

3. Fixed an issue where inquiries to the logical drive would succeed even after the drive is physically removed.

1. Added POST messages informing users to upgrade their HDD firmware for certain models of hard drives to the latest available firmware version on the HP web site.


Version:2.68(A) (8 Jun 2006)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue that can occur during configuration (with the ACU) of an MSA20 or MSA500. In a Windows environment, the issue can result in a blue-screen condition.

2. Disabled a function designed to detect a condition where a SCSI disk drive unexpectedly changes its SCSI ID. This function was previously part of the FW for the SA-6400, SA-641 and SA-642 only.

Version:2.58(B) (6 May 2006)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue with the component installer that may cause this component to not be recognized under the Windows Preinstallation Environment (Windows PE). If you have previously upgraded to version 2.58 firmware another update is not needed.

2. Fixed an issue that causes the HP Insight Management Agents to display incorrect characters for the DL360 G4.

3. Improved event messages when the Smart Array 6400 is installed with two MSA20 enclosures. 'Box 1' or 'Box 2' is indicated in the event message for a disk drive removal or failure event.

4. Modified the PCI-X timing to prevent the Smart Array 641/642 and 6i from possibly becoming unresponsive during read requests when installed in a ProLiant DL760G2.

1. Added support for the controller firmware to place a Monitoring and Performance stamp (M&P) on the disk drive, if it is missing from the drive.

2. Added split-mirroring support and a mirroring re-synchronization feature. This allows a RAID 1 volume to be split into two RAID 0 volumes and then combine the two RAID 0 volumes into a single RAID 1 volume.

3. Added an enhancement to allow an occasional SCSI command timeout without downshifting the SCSI bus to a lower speed.

4. Enhanced performance for drive rebuilds and RAID 5 and RAID 6 (ADG) configurations.

5. Added support for the 512MB Battery-Backed Write Cache (BBWC) option.

6. Added POST message 1717 'Disk Drive(s) Reporting OVERHEATED Condition'.

7. Updated POST message 1794 'Array Accelerator batteries have failed to charge and should be replaced'. This POST message will now display if this condition has occurred when no logical volumes are present or if cache has already been disabled.


Version:2.48(A) (30 Aug 2005)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated the battery charging firmware to reduce the frequency and duration of battery charging cycles. This helps prevent overcharging the battery, which can contribute to premature battery failures. This also reduces the time required for a battery recharge cycle to complete.

Updated the battery firmware to improve the sensing and reporting of battery health. This helps prevent battery status messages from alternating or indicating false status.

Updated the battery firmware to reduce the chances of deep discharging the battery. This helps to maintain the capacity of the battery in the event data was trapped in the cache over the specified backup duration.

Updated the battery firmware to keep the charge capacity during a controller firmware update. This helps prevent the inconvenience of battery back write cache becoming temporarily disabled due to a required recharge following a battery firmware update.


Version:2.36(A) (26 Jan 2005)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed an interrupt handling issue that can cause a server to reboot when using Microsoft Remote Installation Services (RIS). For more details, refer to Customer Advisory EM041123_CW01


Version:2.34(A) (17 Dec 2004)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed an issue where the battery status may be falsely reported as “failed” even though the cache module is “enabled.” Refer to Customer Advisory EX040528_CW01 for additional information.


Type:Firmware - Storage Controller
Version:2.84(A)(15 Jul 2008)
Operating System(s):
Microsoft Windows 2000
Microsoft Windows Server 2003
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Storage Server 2003
Microsoft Windows Unified Data Storage Server 2003 x64 Edition

Description

This Smart Component contains firmware for the Compaq Smart Array 6i Controller.

Installation Instructions

Prerequisites:
This Smart Array firmware will recommend updates for some SCSI disk drive models after the Smart Array firmware has been installed. To avoid notification during the POST routine, update any applicable hard disk drives before updating the Smart Array firmware. Click here to obtain the list of affected disk drive models.

To ensure the integrity of your download, HPE recommends verifying your results with the following SHA-256 Checksum values:

0277860584fc9589d91baaf8581e802acc4252a2d8a858e07037bfd5fcfffc6fcp009357.exe
7f11ed590b9c3e188ad0190f5e5119e84dfd7dd566d356ba9d677a6a160a2935cp009357.md5

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:
Place the Smart Component in a temporary directory.

Double-click on the Smart Component.

Follow the directions given by the Smart Component.

Reboot your system if you would like the update to take effect immediately.

Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Important:

The firmware update Version 2.48 contains critical bug fixes and is the minimum version required. Please perform the update at your earliest convenience.

HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps:

  • Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.
  • Place the firmware to be updated in the directory, /compaq/swpackages on the USB key.
  • Run Autorun from _autorunautorun_win.exe on the Firmware Maintenance CD from the USB key on a system
  • Select the Firmware Update tab
  • Click on the Install Firmware link to launch the HP Smart Update Manager
  • Follow the GUI to install the firmware on remote servers

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis initialization and I/O writes occurring on Raid 1 or Raid 1+0 volumes. This has only been observed in a rigorous test environment and has not been reported in a production environment.
  • Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked 'OK', prior to completing the rebuilding process.
  • Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes.

Important

The firmware update Version 2.48 contains critical bug fixes and is the minimum version required. Please perform the update at your earliest convenience.

HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps:

  • Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.
  • Place the firmware to be updated in the directory, /compaq/swpackages on the USB key.
  • Run Autorun from _autorunautorun_win.exe on the Firmware Maintenance CD from the USB key on a system
  • Select the Firmware Update tab
  • Click on the Install Firmware link to launch the HP Smart Update Manager
  • Follow the GUI to install the firmware on remote servers

Revision History

Version:2.84(A) (15 Jul 2008)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis initialization and I/O writes occurring on Raid 1 or Raid 1+0 volumes. This has only been observed in a rigorous test environment and has not been reported in a production environment.
  • Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked 'OK', prior to completing the rebuilding process.
  • Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes.

Version:2.80(B) (23 Jan 2008)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated the component installer. If you have previously updated to version 2.80, another update is not needed.

  • Fixed an issue that would downshift the entire bus for a single parity error.
  • Fixed a bus fault issue on dual bus I/O modules.
  • Changed the SCSI ID detection algorithm for SCSI disk drive that unexpectedly changes its SCSI ID, in configurations involving duplex backplanes.
  • Improved cache flushing and performance.
  • Updated the volume inquiry command for “Windows Server 2008” compliance.

Version:2.80(A) (25 Sep 2007)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • Fixed an issue that would downshift the entire bus for a single parity error.
  • Fixed a bus fault issue on dual bus I/O modules.
  • Changed the SCSI ID detection algorithm for SCSI disk drive that unexpectedly changes its SCSI ID, in configurations involving duplex backplanes.
  • Improved cache flushing and performance.
  • Updated the volume inquiry command for “Windows Server 2008” compliance.

Version:2.76(A) (20 Mar 2007)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

  • Updated recommended hard drive firmware list with models that have been experiencing excessive SCSI command timeouts. When one of these drives is present, user will see a POST message recommending he upgrade the drive’s firmware. Failure to upgrade may result in the bus down-shifting from Ultra 320 to Ultra 3.

Version:2.74(A) (10 Jan 2007)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue where Windows Server x64 would hang or blue screen when the Smart Array driver is installed or upgraded on a system that has greater than 7GB RAM.

2. Fixed Array behavior to prevent unwanted device migrations by detecting conditions, where a SCSI disk drive unexpectedly changes its SCSI ID.

3. Fixed an issue where inquiries to the logical drive would succeed even after the drive is physically removed.

1. Added POST messages informing users to upgrade their HDD firmware for certain models of hard drives to the latest available firmware version on the HP web site.


Version:2.68(A) (8 Jun 2006)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue that can occur during configuration (with the ACU) of an MSA20 or MSA500. In a Windows environment, the issue can result in a blue-screen condition.

2. Disabled a function designed to detect a condition where a SCSI disk drive unexpectedly changes its SCSI ID. This function was previously part of the FW for the SA-6400, SA-641 and SA-642 only.

Version:2.58(B) (6 May 2006)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

1. Fixed an issue with the component installer that may cause this component to not be recognized under the Windows Preinstallation Environment (Windows PE). If you have previously upgraded to version 2.58 firmware another update is not needed.

2. Fixed an issue that causes the HP Insight Management Agents to display incorrect characters for the DL360 G4.

3. Improved event messages when the Smart Array 6400 is installed with two MSA20 enclosures. 'Box 1' or 'Box 2' is indicated in the event message for a disk drive removal or failure event.

4. Modified the PCI-X timing to prevent the Smart Array 641/642 and 6i from possibly becoming unresponsive during read requests when installed in a ProLiant DL760G2.

1. Added support for the controller firmware to place a Monitoring and Performance stamp (M&P) on the disk drive, if it is missing from the drive.

2. Added split-mirroring support and a mirroring re-synchronization feature. This allows a RAID 1 volume to be split into two RAID 0 volumes and then combine the two RAID 0 volumes into a single RAID 1 volume.

3. Added an enhancement to allow an occasional SCSI command timeout without downshifting the SCSI bus to a lower speed.

4. Enhanced performance for drive rebuilds and RAID 5 and RAID 6 (ADG) configurations.

5. Added support for the 512MB Battery-Backed Write Cache (BBWC) option.

6. Added POST message 1717 'Disk Drive(s) Reporting OVERHEATED Condition'.

7. Updated POST message 1794 'Array Accelerator batteries have failed to charge and should be replaced'. This POST message will now display if this condition has occurred when no logical volumes are present or if cache has already been disabled.


Version:2.48(A) (30 Aug 2005)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Updated the battery charging firmware to reduce the frequency and duration of battery charging cycles. This helps prevent overcharging the battery, which can contribute to premature battery failures. This also reduces the time required for a battery recharge cycle to complete.

Updated the battery firmware to improve the sensing and reporting of battery health. This helps prevent battery status messages from alternating or indicating false status.

Updated the battery firmware to reduce the chances of deep discharging the battery. This helps to maintain the capacity of the battery in the event data was trapped in the cache over the specified backup duration.

Updated the battery firmware to keep the charge capacity during a controller firmware update. This helps prevent the inconvenience of battery back write cache becoming temporarily disabled due to a required recharge following a battery firmware update.


Version:2.36(A) (26 Jan 2005)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed an interrupt handling issue that can cause a server to reboot when using Microsoft Remote Installation Services (RIS). For more details, refer to Customer Advisory EM041123_CW01


Version:2.34(A) (17 Dec 2004)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed an issue where the battery status may be falsely reported as “failed” even though the cache module is “enabled.” Refer to Customer Advisory EX040528_CW01 for additional information.


Usb Compliance Hard Disk Controller Driver Download For Windows Xp

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.